as vision medical systems we start to distribution of innova sound usb ultrasound systems and defibrillator in romania
information in www.vision medical.ro
Diagnostic Imaging Products |
InnovaSound 3.5 MHZ – General Purpose Probe*
Direct Medical System's 3.5MHz GP Pocket Portable Ultrasound Probe System* see detail....
|
InnovaSound 5.0 MHZ – General Purpose Probe*
Direct Medical System's 5.0MHz GP Pocket Portable Ultrasound Probe System* see detail.... |
InnovaSound 7.5 MHZ – Small Parts
Direct Medical System's 7.5MHz GP Pocket Portable Ultrasound Probe System. see detail....
|
InnovaSound 7.5 MHZ – Endo-Cavity Probe
Direct Medical System's 7.5MHz Endo Cavity Pocket Portable Ultrasound Probe System. see detail.... |
InnovaSound 12.5 MHZ – Vascular Probe
Direct Medical System's 12.5 MHz MV Pocket Portable Ultrasound Probe System. see detail....
|
|
|
|
|
Synchronized Cable |
4 lead ECG Cable |
Adult / Pediatric Paddles kit |
|
|
|
|
|
|
|
|
|
|
TECHNICAL SPECIFICATION
SpO2(Pulse Oximeter) : |
: |
Yes |
Max. Charging time to 360 joule |
: |
10 seconds |
|
: |
5-7-10-20-30-50-100-150-200-250-300-360 |
Battery charging time |
: |
5 Hours |
Discharge number with charged battery |
: |
100+ shock (360 Joule) |
Sensitivity Selection |
: |
0,5 / 1 / 2 |
Derivations |
: |
DI-DII-DIII (4 lead ECG cable |
Freeze |
: |
Yes |
ECG/Monitoring time |
: |
10 hours |
ECG signal inputs |
: |
ECG electrodes and Paddles |
Printing speed |
: |
25-50 mm/sec |
Working temperature and humidity |
: |
0-40 °C and %30-%95 RH |
Dimensions |
: |
403x152x324 mm |
|
|
AC 230V/1A 50-60 Hz |
|
: |
30-100, 40-120, 40-150, 60-120, 60-150 and Alarm-off |
Weigth |
: |
8kg |
LCD Monitor |
: |
240X128 resolution (backlight) |
Patient leakage current |
: |
<0,01mA |
Working temperature and humidity |
: |
0-40°C ve %30-%98 nem oranı |
|
|
|
|
TECHNICAL SPECIFICATION
Max. Charging time to 360 joule |
: |
10seconds |
Energy Selection |
: |
5-7-10-20-30-50-100-150-200-250-300-36 |
Battery charging time: |
: |
5 hours |
Discharge number with charged battery |
: |
100+ shock (360 Joule) |
Sensitivity Selection |
: |
0,5 / 1 / 2 |
Derivations |
: |
DI-DII-DIII (4 lead ECG cable) |
Freeze |
: |
Yes |
ECG/Monitoring time |
: |
10 hours |
ECG signal inputs |
: |
ECG electrodes and Paddles |
Printing speed |
: |
25-50 mm/sec |
Working temperature and humidity |
: |
0-40 °C and %30-%95 RH |
Weigth |
: |
8kg |
Dimensions |
: |
403x152x324 mm |
Mains supply votage |
: |
AC 230V/1A 50-60 Hz |
Alarm Limits Selection |
: |
30-100, 40-120, 40-150, 60-120, 60-150 and Alarm-off |
LCD Monitor |
: |
240X128 resolution (backlight) |
Patient leakage current |
: |
<0,01mA |
|
|
|
|
|
|
|
|
|
TECHNICAL SPECIFICATION
Max. Charging time to 360 joule |
: |
8 seconds |
Battery charging time |
: |
5 hours |
Sync Option |
: |
Available |
Discharge number with charged battery |
: |
100+ shock (360 Joule) |
Classification (93/42/EEC) |
: |
Category II b |
Type |
: |
BF |
Working temperature and humidity |
: |
0-40 °C and %30-%95 RH |
Patiend leakage current |
: |
0,01 mA |
Mains supply votage |
: |
AC 230V/1A 50-60 Hz |
Weigth |
: |
8kg |
Dimensions |
: |
403x152x324 mm |
Energy selection (5-360 Joule) |
: |
5-10-30-50-100-150-200-300-360 |
|
: |
|
|
|
|
|
|